Parapet installation FVP Pulse-V

High economic efficiency
Draught-free and low-noise impulse flow
Gain in usable space

The award-winning PulseVentilation system for maximum efficiency and planning freedom

The parapet unit is ideal for cost-effective refurbishments with limited storey heights, as neither raised or cavity floors nor suspended ceilings are required.

Thanks to the PulseVentilation system, all variants of the FVP family are able to simulate organic air movement to allow buildings to breathe “naturally” through just one façade opening. The very high heat and cold recovery, which can be used all year round, guarantees energy efficiency that is unique in the industry. The transient flow with mixed displacement ventilation results in very high thermal comfort even at low supply air temperatures.

  • Decentralized heating, cooling, dehumidification and filtration with pulsating ventilation through just one façade opening
  • Highly economical thanks to highly efficient heat recovery (heat recovery efficiency up to 90 %) and demand-oriented control concepts
  • Draught-free and low-noise impulse flow up to 130m3/h(260m3/h in hybrid ventilation mode) with optimum ventilation efficiency
  • Large gain in usable space due to elimination of central air conditioning unit, shafts, duct system and fire dampers
  • Lowest power consumption due to minimized pressure losses, corresponds to 10 % of the SFP specification of the EnEV (approx. 20 W per device)
  • Year-round heat recovery reduces the investment costs for the central heat supply

An overview of all variants in the FVP family including technical data can be found in our brochure Decentralized ventilation units.


LTG Connected Intelligence

Demand-based, room-specific ventilation and air conditioning with and without a higher-level building management system. With decentralized control intelligence. Efficient, scalable, bus-compatible.

Corona virus
Here we have compiled the most important facts and information on the operation of ventilation systems. Recommendations for the operation of FVPpulse decentralized ventilation units can be found here.

Technical Data

Technical Data for L_pa= 35 dB(A)

Volume flow up to 130 m³/h on average over the entire cycle Volume flow up to 260 m³/h in hybrid ventilation mode Condensing operation Standard Max. Cooling Output Total: 835 W Room: 595 W 1) Max. Heating Output Total: 2125 W Room: 765 W 2) Heat recovery coefficient >80 % Electrical power consumption 12-40 W 3) Schalldruckpegel Lp(A) 23-36 dB (A)

DWG downloads

Downloads

LTG recommendations Decentral / FVPpulse & Corona
PDF 108 kB
Overview brochure decentralized ventilation units German
PDF 10.11 MB
Presentation of decentralized ventilation units FVP pulse
PDF 2.4 MB
Technical brochure Decentralized ventilation unit FVPpulse-V German
PDF 2.87 MB
Tender text Decentralized ventilation unit FVPpulse-V German
DOC 52.47 kB
Operating instructions Decentralized ventilation unit FVPpulse-V German
PDF 2.97 MB
Technical article Decentralized ventilation unit FVPpulse German
PDF 86.94 kB
Technical article Instationary ventilation technology Facade ventilation unit FVPpulse German
PDF 1.66 MB

Impressions